We also service existing generator gas connections — checking pressure under load, fixing leaks, and making sure your generator gets the fuel flow it needs when it matters.
When to call us about your generator
- New standby generator needs a propane connection
- Generator starts but stumbles, surges or shuts down under load
- Low fuel pressure faults on the generator controller
- Adding a generator to a home with existing propane appliances
- Corroded or damaged gas piping or flex connector at the generator pad
- Smell of gas near the generator or regulator
Why the gas line matters so much
Standby generators can be the largest propane load in the house. A 22 kW generator at full output can use more gas than a furnace, water heater and range combined. If the line or regulator is undersized, the generator may run fine during a no-load weekly exercise and then fail during a real outage when the whole house is on it.
We calculate the combined demand, size the pipe for the actual run length, and verify pressure at the generator while it's under load.
Working with your electrician and supplier
Generator installations involve three trades: the electrician wires the transfer switch, your propane supplier provides the tank and fuel, and we handle the gas piping and appliance connection. We're happy to coordinate with whoever you already work with. Your supplier must confirm the tank is large enough for generator run time — a small tank can run dry during a multi-day outage.
Ongoing service
Generator manufacturers recommend periodic maintenance on the engine; we focus on the fuel side. A yearly check of regulator pressure, connector condition and leak tightness is a smart add-on to your maintenance plan.